YMC*GEL for preparative HPLC has various available functional groups, such as reversed-phase and normal-phase, and also various particle sizes from 3 µm with high-resolution to 150 µm for open column chromatography. YMC*GEL is able to work for a long period of time without particle breakage, as it uses high-density and high-strength silica gel. YMC*GEL/YMC*GEL HG packing materials are widely used both domestically and internationally.
The high mechanical stability of YMC*GEL HG is demonstrated by means of repeated measurements with a dynamic axial compression column (DAC). Even after more than 10 repacking cycles with the same material, the pressure does not increase. The absence of fines is proven by a constant backpressure.
Packing conditions | |
Column size | 100 X 50 mmI.D. |
---|---|
Packing pressure | 6.5 MPa |
Test conditions | Eluent | methanol/water(85/15) |
Flow rate | 50 mL/min |
YMC*GEL/YMC*GEL HG are available with various functional groups and also with wide pores. Therefore, this material is suitable for the preparation of peptides, such as insulin and proteins. YMC*GEL HG can make scaling up from analytical scale to preparative scale easy, as it has the same performance as that of YMC-Pack.
Analytical condition (1), (3) | |
Column | YMC-Pack C8 (5 µm, 200 Å) 150 X 4.6 mmI.D. |
---|---|
Eluent | A) water/TFA (100/0.1) B) acetonitrile/TFA (100/0.1) 27%B (0-5 min) 27-40%B (5-20 min) |
Flow rate | 0.8 mL/min |
Temperature | ambient |
Detection | UV at 220 nm |
Preparative condition (2) | |
Column | YMC*GEL C8 (10 µm, 200 Å)
150 X 50 mmI.D. |
---|---|
Eluent | A) water/TFA (100/0.1) B) acetonitrile/TFA (100/0.1) 27%B (0-5 min) 27-40%B (5-20 min) |
Flow rate | 100 mL/min |
Temperature | ambient |
Detection | UV at 220 nm |
Packing material | Particle size (µm) |
Pore size (Å) |
Characteristics |
---|---|---|---|
ODS-A | 3, 5, 75, 150 | 120, 200, 300 |
|
ODS-A-HG | 7, 10, 15, 20, 50 | ||
ODS-AM | 3, 5 | 120 |
|
ODS-AQ | 3, 5 | 120, 200 |
|
ODS-AQ-HG | 7, 10, 15, 20, 50 | ||
C8 | 3, 5 | 120, 200, 300 |
|
C8-HG | 10, 15, 20, 50 | ||
C4 | 3, 5 | 120, 200, 300 |
|
C4-HG | 10, 15, 20, 50 | ||
TMS | 3, 5 | 120 |
|
TMS-HG | 10, 15, 20, 50 | ||
Ph(Phenyl) | 3, 5 | 120 |
|
Ph-HG | 10, 15, 20, 50 | ||
CN | 3, 5 | 120 |
|
CN-HG | 10, 15, 20, 50 | ||
SIL | 3, 5, 75, 150 | 60, 120, 200, 300 |
|
SIL-HG | 10, 15, 20, 50 | ||
Diol | 3, 5 | 60, 120, 200, 300 |
|
Diol-HG | 10, 15, 20, 50 | ||
NH2 | 5 | 120 |
|
NH2-HG | 10, 15, 20, 50 |
Packing material | Particle size (µm) |
Pore size (Å) |
---|---|---|
ODS-A | 75, 150 | 120 |
SIL | 75, 150 | 120 |